1

Technical data
TYPE
H
Ød/DE
Z
L
m
a x a x h
TYPE
 
m
mm
mm/m
mm
kg
m
S-30P/6-3
3,0
60/143
27
100
29
0,3 x 0,3 x 0,75
F75/200
S-40P/6-3
4,0
60/143
20
100
37
0,3 x 0,3 x 1,0 (0,75)*
F100/200 (F75/200)*
S-50P/6-3
5,0
60/143
16
100
45
0,3 x 0,3 x 1,0
F100/200

* – The foundation type depends on the post load
Ød – other mounting diameters should be specified in the inquiry or order

Strength data
TYPE
Weight of iluminaires

Wind zone acc, to PN EN 1991-1-4
Permissible surface of luminaires [m²]

MF
 
kg
I≤300m a.s.l.
I≤500m a.s.l.
II≤300m a.s.l..
III≤950m a.s.l.
kNm
S-30P/6-3 50 2,904 2,222 2,045 0,450 2,3
S-40P/6-3 50 1,990 1,500 1,374 0,380 3,1
S-50P/6-3 50 1,322 0,973 0,883 0,171 3,1

Downloadable:

Ikony- pdf Catalog page